11kV HT Metering & Switching Panel (3CT/ 3PT)

11KV Metering & VCB (3CT/ 3PT)
11KV 3 VCB RMU
11KV 2LBS+1VCB etc.,

Features:

  • Omega make current Transformer(resin cast) class 0.2/0.25 the insulation level is 15/ 35/ 95kV.
  • Omega make potential transformer(Resin cast)  Class 0.2 IS:3156. The insulation level is 12/35/95kV.
  • L&T make Electronic Trivector Meter Class 0.25.
  • The Terminal BLock 3ph. 4 wire front connection.
  • Sealing facility provided as per EB Rules.
  • Tamper proof.

Out going

  • Vacuum Circuit Breaker, Rating: 630-200A(manual & electric operating)
  • Current Transformer, Class 1-5P10
  • Potential Transformer, Class 1/0.5
  • Ammeter, Voltmeter with selector switches
  • Insulation level: 12/ 28/ 75/kV

Optional Accessories:

  • IDMT Relay(CBD-31)
  • Auxillary Relay (VAA-33)
  • Annunciation Scheme, other relays and accessories as per customer specificaitons
  • Panel is extensible.

11kV HT Metering Cubical Panel (3CT/ 3PT)

Features:

Incoming:

  • Omega make Current Transformer (Resin cast) Class 0.2/0.25. The insulation level is 15/ 35/95kV.
  • Omega make Potential Transformer (Resin cast) Class 0.2 IS:3156. The insulation level is 15/ 35/95kV.
  • L&T make Electronic Trivector Meter Class 0.25.
  • The Terminal Block 3ph.4 wire front connection.
  • Sealing facility provided as per EB Rules.
  • Tamperproof

11kV HT Metering and Switching panel (3CT/ 3PT)

Features:

Incoming:

  • Omega make Current Transformer (Resin cast) Class 0.2/0.25. The insulation level is 15/ 35/95kV.
  • Omega make Potential Transformer (Resin cast) Class 0.2 IS:3156. The insulation level is 15/ 35/95kV.
  • L&T make Electronic Trivector Meter Class 0.25.
  • The Terminal Block 3ph.4 wire front connection.
  • Sealing facility provided as per EB Rules.
  • Tamper proof

Outgoing

  • OMEGA make Load Break switch 630A.
  • HT HRC fuses of suitable rating
  • The insulation level is 12/28/75KV

LBS/ VCB, Indoor/ Outdoor

Features:

Incoming:

  • OMEGA make Load Break Switch with Earth Switch and Interlock, 630A, 26.3kA IS:9920/IEC 60265
  • Earth Fault Indicator with CBCT as per EB standard.
  • VCB Type optional

Outgoing

  • OMEGA make Load Break switch with fuse trip, 630A, 26.3kA IS 9920/ IEC 60265
  • IS.9920 Vacuum Circuit Breaker IS:13118
  • IDMT Relay Optional
  • Insulation level 12/28/75 kV for LBS

Various RMU Options (extensible)

  • RMU with 2 VCBs and LBs
  • RMU with VCBs only
  • RMU with LBS only
  • RMU with 2 LBS and VCB